Environmental Management
Sustainability Report 2008 |
|
 |
| Emission Data of Production Facilities |
 |
| The following data for all works, plants and facilities of Kobe Steel and its major group companies covers exhaust gas and wastewater emissions as well as emissions or transfers of the main chemical substances covered by the PRTR Law. For exhaust gases the tables show emissions of NOx, dust and dioxins, and for wastewater chemical oxygen demand (COD), in some cases biochemical oxygen demand (BOD), suspended solids (SS), oil and dioxins. Regulation values are also given in all cases. |
|
| Air Quality Data |
 |
| * |
Regulation values are based on the Air Pollution Control Law, prefectural government ordinances, and the Law Concerning Special Measures against Dioxins. |
| * |
Unit: ppm for NOx, mg/Nm3 for dust, and ng-TEQ/ Nm3 for dioxins |
|
| Water Quality Data |
 |
| * |
Regulation values are based on the Water Pollution Control Law, prefectural government ordinances, the Law Concerning Special Measures against Dioxins, the Sewage Water Law, and municipal government ordinances concerning sewage water. |
| * |
Unit: mg/l, pg-TEQ/l for dioxins |
| * |
ND (Not detected): Below the quantitative limit |
|
| Chemical substances |
 |
| * Unit: kg (mg-TEQ for dioxins) |
Kakogawa Works
1 Kanazawacho
Kakogawa, Hyogo 675-0137
Tel +81-79-436-1111 Fax +81-79-436-1400
Main Products:
Steel plate, hot-rolled sheet, cold-rolled sheet, coated sheet, wire rod
Air
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler
Boiler
Reheating furnace |
250
190
100 |
132
109
60 |
| Dust |
Boiler
Boiler
Reheating furnace |
100
70
100 |
18
26
2 |
| Dioxins |
Sintering plant
Industrial waste incinerator |
1
5 |
0.087
0.25 |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
20
40
1.51)
10 |
3.8
12
<1
0.0018 |
|
1) Liquid petroleum
Company included in water quality data: Kansai Coke and Chemicals Co., Ltd.
| Chemical Substances |
Total substances used: 23 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Toluene |
26,000 |
0 |
0 |
0 |
0 |
410 |
Painting |
| Xylene |
12,000 |
0 |
0 |
0 |
0 |
2,400 |
Painting |
| Hydrogen fluoride and its water-soluble salts |
0 |
12,000 |
0 |
0 |
0 |
1,800 |
Rolling, pickling of steel surface |
|
|
Kobe Works
2 Nadahama Higashicho, Nada-ku
Kobe, Hyogo 657-0863
Tel +81-78-882-8030 Fax +81-78-882-8290
Main Products:
Steel wire rod and bar
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler
Boiler
Reheating furnace |
250
130
100 |
190
90
43 |
| Dust |
Boiler
Boiler
Reheating furnace |
200
50
150 |
92
<1
12 |
| Dioxins |
Industrial waste incinerator |
10 |
0.74 |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
20
40
1.51)
10 |
5
15
<1
0.00096 |
|
1) Liquid petroleum
| Chemical Substances |
Total substances used: 13 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Manganese and its compounds |
13 |
160 |
0 |
0 |
0 |
410,000 |
Steelmaking process |
| Chromium and trivalent chromium compounds |
6.8 |
7.9 |
0 |
0 |
0 |
27,000 |
Steelmaking process |
| Vanadium pentoxide |
0 |
7.9 |
0 |
0 |
0 |
35,000 |
Steelmaking process |
|
|
Takasago Works
3-1, Araicho Shinhama 2-chome
Takasago, Hyogo 676-8670
Tel +81-79-445-7111 Fax +81-79-445-7231
Main Products:
Steel castings and forgings, titanium products, steel powder, industrial machinery, compressors, equipment for the energy and nuclear fields
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler
Melting furnace
Reheating furnace |
130
150
200 |
51
44
79 |
| Dust |
Boiler
Melting furnace
Reheating furnace |
50
100
100 |
2
9
2 |
| Dioxins |
Electric arc furnace (for steel powder) |
5 |
0.000026 |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
15
26
1.5
- |
5.5
20
<0.5
- |
|
Company included in water quality data: Kobelco Research Institute Inc. Sputtering Target Division
| Chemical Substances |
Total substances used: 12 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Methylene chloride |
60,000 |
0 |
0 |
0 |
0 |
0 |
Degreasing cleaning of titanium scrap |
| Xylene |
79,000 |
0 |
0 |
0 |
0 |
380 |
Painting |
| Toluene |
37,000 |
0 |
0 |
0 |
0 |
870 |
Contained in binding agent for steel powder |
|
|
Shinko Kenzai, Ltd.
46 Marushimacho
Amagasaki, Hyogo 660-0086
Tel +81-6-6418-2621 Fax +81-6-6418-6701
Main Products:
Guardrails, grating, anti-slip steel plate, aluminum road material
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler |
150 |
31 |
| Dust |
Boiler |
100 |
<1 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
300
300
51)
- |
19
30
5.5*
- |
|
* Oil exceeded in March 2008; report to government authorities and countermeasures completed
| Chemical Substances |
Total substances used: 1 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Xylene |
9,900 |
0 |
0 |
0 |
0 |
0 |
Painting |
|
|
Shinko Wire Company, Ltd. (in Amagasaki)
10-1 Nakahamacho
Amagasaki, Hyogo 660-0091
Tel +81-6-6411-1071 Fax +81-6-6411-9644
Main Products:
Steel wire products, wire for prestressed concrete, steel strand for prestressed concrete, steel bar for prestressed concrete
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler
Reheating furnace |
150
130 |
39
20 |
| Dust |
Boiler
Reheating furnace |
50
100 |
<1
29 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
20
30
22
- |
5.3
11
<1
- |
|
| Chemical Substances |
Total substances used: 5 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Tetrachloroethylene |
3,900 |
0 |
0 |
0 |
0 |
1,500 |
Degreasing cleaning |
| Lead and its compounds |
0 |
11 |
0 |
0 |
0 |
4,100 |
Lead for heat treatment |
| Barium chloride |
0 |
230 |
0 |
0 |
0 |
1,400 |
Heat treatment process |
|
|
Shinko Wire Company, Ltd. (in Onoecho)
128 Imafuku, Onoecho
Kakogawa, Hyogo 675-0027
Tel +81-79-424-2681 Fax +81-79-424-2686
Main Products:
Steel wire products, wire for prestressed concrete, steel strand for prestressed concrete, steel bar for prestressed concrete
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler
Reheating furnace
Cogeneration equipment |
150
170
600 |
82.0
15.0
290 |
| Dust |
Boiler
Reheating furnace
Cogeneration equipment |
100
250
50 |
<1
15
<2 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
15
25
2
- |
4.2
4
0.4
- |
|
| Chemical Substances |
Total substances used: 4 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Lead and its compounds |
0 |
3 |
0 |
0 |
0 |
2,600 |
Lead for heat treatment |
| Boron and its compounds |
0 |
140 |
0 |
0 |
0 |
43 |
Processing |
| Toluene |
0 |
0 |
0 |
0 |
0 |
0 |
Cable coating |
|
|
Kobe Special Tube Co., Ltd.
13-1 Chofu Minatomachi
Shimonoseki, Yamaguchi 752-0953
Tel +81-832-46-3781 Fax +81-832-45-1092
Main Products:
Seamless stainless steel tube, precision tube, specialty tube
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Reheating furnace |
180 |
78 |
| Dust |
Reheating furnace |
200 |
8 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
25
50
5
- |
10.7
8.0
0.5
- |
|
| Chemical Substances |
Total substances used: 2 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Hydrogen fluoride and its water-soluble salts |
120 |
3,400 |
0 |
0 |
0 |
7 |
Pickling |
| Trichloroethylene |
0 |
0 |
0 |
0 |
0 |
0 |
Lubricant |
|
|
Shinko Bolt, Ltd.
17 Futamata Shinmachi
Ichikawa, Chiba 272-0002
Tel +81-47-328-6551 Fax +81-47-328-6558
Main Products:
High strength bolts, various other bolts
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
NA |
- |
- |
| Dust |
NA |
- |
- |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
25
70
-
- |
12
8
-
- |
|
| Chemical substances: No handling of substances requiring PRTR report |
|
Ceratechno Co., Ltd. (Akashi Plant)
11-70, Kisaki 5-chome
Akashi, Hyogo 673-0037
Tel +81-78-923-8678 Fax +81-78-923-8397
Main Products:
Refractory bricks, monolithic refractories, burnt lime
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler
Dry Kiln |
180
180 |
48
59 |
| Dust |
Boiler
Dry Kiln |
300
300 |
8
30 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
70
60
3.8
- |
17.7
22.8
2.4
- |
|
| Chemical Substances |
Total substances used: 6 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Ethylene glycol |
38,000 |
0 |
0 |
0 |
0 |
42 |
Brick binder |
| Chromium and trivalent chromium compounds |
0 |
0 |
0 |
0 |
0 |
9,900 |
Filler sand material |
| Phenol |
360 |
0 |
0 |
0 |
0 |
5.3 |
Brick binder |
|
|
Ceratechno Co., Ltd. (Bizen Plant)
2835-7 Honami
Bizen, Okayama 705-0033
Tel +81-869-67-0011 Fax +81-869-67-1346
Main Products:
Refractory bricks, monolithic refractories, burnt lime
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Firing furnace |
450 |
25 |
| Dust |
Firing furnace |
200 |
8.8 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
-
-
-
- |
-
-
-
- |
|
| Chemical Substances |
Total substances used: 4 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Ethylene glycol |
23,000 |
0 |
0 |
0 |
0 |
140 |
Brick binder |
| Phenol |
10,000 |
0 |
0 |
0 |
0 |
63 |
Brick binder |
| Boron and its compounds |
0 |
0 |
0 |
0 |
0 |
51 |
Castable and brick materials |
|
|
Tesac Wirerope Co., Ltd.
11-1 Nishiki Nakamichi
Kaizuka, Osaka 597-8501
Tel +81-72-432-9251 Fax +81-72-432-2339
Main Products:
Wire rope
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler
Reheating furnace |
150
150 |
37
14 |
| Dust |
Boiler
Reheating furnace |
100
200 |
3
0 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
-
300
51)
- |
-
57
0.6
- |
|
1) Liquid petroleum
| Chemical Substances |
Total substances used: 1 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Methylene chloride |
6,300 |
0 |
0 |
0 |
0 |
0 |
Wire drawing process |
|
|
Nippon Koshuha Steel Co., Ltd.
10-15, Hachimanmachi 3-chome
Imizu, Toyama 934-8502
Tel +81-766-84-3181 Fax +81-766-84-3468
Main Products:
Specialty steel forged products (die steel, plastic mold steel, other precision forged steels), specialty rolled steel
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler
Reheating furnace |
150
150 |
50
82 |
| Dust |
Boiler
Melting furnace
Reheating furnace |
200
100
200 |
59
1.7
5.9 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
20
50
3
- |
6
17
2
- |
|
| Chemical Substances |
Total substances used: 8 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Hydrogen fluoride and its water-soluble salts |
790 |
10,000 |
0 |
9 |
0 |
500,000 |
Secondary raw material for steelmaking |
| Chromium and trivalent chromium compounds |
36 |
110 |
0 |
0 |
0 |
59,000 |
Raw material for steelmaking |
| Manganese and its compounds |
2,300 |
180 |
0 |
0 |
0 |
51,000 |
Raw material for steelmaking |
|
|
Kansai Coke and Chemicals Co., Ltd.
(Kakogawa Plant)
7 Kanazawacho
Kakogawa, Hyogo 675-0137
Tel +81-79-436-1500 Fax +81-79-435-1626
Main Products:
Coke, coke oven gas, chemical products
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Coke oven |
350 |
269 |
| Dust |
Coke oven |
150 |
8 |
| Dioxins |
NA |
- |
- |
|
| Water Water quality data is included in Kakogawa Works. |
| Chemical Substances |
Total substances used: 5 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Benzene |
5,300 |
0 |
0 |
0 |
0 |
0 |
Coke oven |
| Toluene |
1,400 |
0 |
0 |
0 |
0 |
0 |
Coke oven |
| Xylene |
240 |
0 |
0 |
0 |
0 |
0 |
Coke oven |
|
|
Shinko Kobe Power Inc.
2 Nadahama Higashicho, Nada-ku
Kobe, Hyogo 657-0863
Tel +81-78-882-8036 Fax +81-78-882-8037
Main Products:
Generation and wholesale supply of electricity
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler |
24 |
33* |
| Dust |
Boiler |
10 |
3 |
| Dioxins |
NA |
- |
- |
|
* NOx exceeded in December 2007; report to government authorities and countermeasures completed
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
20
40
1.5
- |
4.1
12
<1
- |
|
| Chemical Substances |
Total substances used: 1 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Hydrazine |
0 |
0 |
0 |
0 |
0 |
0 |
Power generation boiler |
|
|
Fujisawa Industrial Operations
100-1 Miyamae
Fujisawa, Kanagawa 251-8551
Tel +81-466-20-3111 Fax +81-466-20-3289
Main Products:
Semi-automatic welding wires
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
NA |
- |
- |
| Dust |
NA |
- |
- |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
60
90
10
- |
15
12
2.7
- |
|
Company included in water quality data: Shinko Taseto Co., Ltd.
| Chemical substances: No handling of substances requiring PRTR report |
|
Ibaraki Plant
2-19 Higashi-Unobecho
Ibaraki, Osaka 567-0879
Tel +81-72-621-2111 Fax +81-72-620-2051
Main Products:
Covered welding electrodes, semi-automatic welding wires, fluxes, backing materials
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler
Calcination furnace (Firing furnace)
Dry Kiln |
150
110*1
230 |
33.7
75.9
55.6 |
| Dust |
Boiler
Calcination furnace (Firing furnace)
Dry Kiln |
100
250
200 |
3.5
1
2.9 |
| Dioxins |
NA |
- |
- |
|
*1: Facilities control figures based on Osaka Prefecture's guideline index for reducing NOx volumes
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
-
300 1)
5 1) 2)
- |
-
7.0
1.0
- |
|
1) Ibaraki municipal sewage ordinance
2) Liquid petroleum
| Chemical Substances |
Total substances used: 7 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Manganese and its compounds |
15 |
0 |
0 |
0 |
0.1 |
21,000 |
Added to welding wire |
| Molybdenum and its compounds |
2.5 |
0 |
0 |
0 |
0 |
18,000 |
Added to welding wire |
| Chromium and trivalent chromium compounds |
2.2 |
0 |
0 |
0 |
0.1 |
2,800 |
Added to stainless steel welding wire |
|
|
Saijo Plant (Welding)
6400-1, Saijocho Misonou
Higashi-Hiroshima, Hiroshima 739-0024
Tel +81-82 423-3311 Fax +81-82-420-0038
Main Products:
Covered welding electrodes, high-functional materials
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Dry Kiln |
230
|
41 |
| Dust |
Dry Kiln |
200 |
5 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
BOD
SS
Oil
Dioxins |
-
-
5
- |
-
-
1.6
- |
|
| Chemical Substances |
Total substances used: 2 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Manganese and its compounds |
23 |
0 |
0 |
0 |
0 |
7,900 |
Added to welding electrode |
| Xylene |
320 |
0 |
0 |
0 |
0 |
0 |
Contained in kerosene |
|
|
Shinko Actec Co., Ltd.
682 Iwanaka, Hidakacho
Toyooka, Hyogo 669-5302
Tel +81-796-42-1212 Fax +81-796-42-1218
Main Products:
High functional filters, odor eliminators
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
NA |
- |
- |
| Dust |
NA |
- |
- |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
-
-
Mineral oil, 5mg/l; animal fat and vegetable oil, 30mg/l
- |
-
-
<0.5
- |
|
| Chemical Substances |
Total substances used: 1 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Manganese and its compounds |
0 |
0 |
0 |
0 |
0.8 |
230 |
Raw material in high functional filters |
|
|
Shinko Taseto Co., Ltd.
100-1 Miyamae
Fujisawa, Kanagawa 251-8551
Tel +81-466-20-3131 Fax +81-466-20-3115
Main Products:
Flux-cored welding wires, solid welding wires
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
NA |
- |
- |
| Dust |
NA |
- |
- |
| Dioxins |
NA |
- |
- |
|
| Water Water quality data is included in Fujisawa Industrial Operations. |
| Chemical Substances |
Total substances used: 6 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Molybdenum and its compounds |
0 |
0 |
0 |
0 |
0 |
3,500 |
Lubricant in drawing process |
Chromium and trivalent chromium compounds
|
0 |
0 |
0 |
0 |
0 |
820 |
Added to welding wire |
| Manganese and its compounds |
0 |
0 |
0 |
0 |
0 |
480 |
Added to welding wire |
|
|
Hanshin Yosetsu Kizai Co., Ltd.
1028-12 Mitsuita
Okayama, Okayama 709-2105
Tel +81-867-24-4181 Fax +81-867-24-4340
Main Products:
Flux for automatic welding
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Firing furnace
Fusion furnace
Dry Kiln |
35
28
30 |
15
10
15 |
| Dust |
Firing furnace
Fusion furnace
Dry Kiln |
15
12
15 |
2
5
13 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
30
30
-
- |
17
2
-
- |
|
| Chemical Substances |
Total substances used: 8 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Manganese and its compounds |
50 |
0 |
0 |
0 |
0 |
16,000 |
Raw material for flux |
| Boron and its compounds |
0.9 |
0 |
0 |
0 |
0 |
280 |
Raw material for flux |
| Chromium & trivalent chromium compounds |
1.2 |
0 |
0 |
0 |
0 |
290 |
Raw material for flux |
|
|
Kobe Welding Wire Co. Ltd.
3-36 Osadanocho
Fukuchiyama, Kyoto 620-0853
Tel +81-773-27-2131 Fax +81-773-27-6358
Main Products:
Solid welding wires
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Reheating furnace
Reheating furnace
Boiler
|
180
150
In grace period |
122
76
102 |
| Dust |
Reheating furnace
Reheating furnace
Boiler
|
200
250
In grace period |
<10
<2
<2 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
300
300
3
- |
3.3
0.4
0.6
- |
|
| Chemical Substances |
Total substances used: 3 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Molybdenum and its compounds |
0 |
0 |
0 |
0 |
0 |
1,600 |
Lubricant in drawing process |
| Inorganic cyanide compounds |
0 |
0 |
0 |
0 |
0 |
720 |
Plating process |
| Water-soluble copper salts |
0 |
0 |
0 |
0 |
13 |
0 |
Plating process |
|
|
| Aluminum & Copper Company |
|
Moka Plant
No. 2 Kogyo Danchi 15 Kinugaoka
Moka, Tochigi 321-4367
Tel +81-285-82-4111 Fax +81-285-84-0231
Main Products:
Aluminum sheet and strip
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler
Melting furnace
Waste incinerator |
180
180
300 |
59
140
160 |
| Dust |
Boiler
Melting furnace
Waste incinerator |
300
300
500 |
61
8
82 |
| Dioxins |
Boiler
Aluminum melting furnace |
10
5 |
0.0000052
0.014 |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
BOD
SS
Oil
Dioxins |
25
50
5
- |
18.1
6.8
1.6
- |
|
1) Liquid petroleum
| Chemical Substances |
Total substances used: 15 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Chromium and trivalent chromium compounds |
0 |
0 |
0 |
0 |
0 |
28,000 |
Surface treatment of aluminum sheet |
| Xylene |
3,700 |
0 |
0 |
0 |
0 |
540 |
Painting process of aluminum sheet |
| Manganese and its compounds |
0 |
0 |
0 |
0 |
0 |
15,000 |
Added to molten aluminum |
|
|
Chofu Works
14-1 Minatomachi, Chofu
Shimonoseki, Yamaguchi 752-0953
Tel +81-832-46-1211 Fax +81-832-46-1271
Main Products:
Aluminum extrusions, fabricated aluminum products, copper sheet and strip
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler
Melting furnace
Reheating furnace |
180
180
180 |
21
80
99 |
| Dust |
Boiler
Melting furnace
Reheating furnace |
300
300
250 |
<5
230
7 |
| Dioxins |
Dioxins Aluminum melting furnace |
5 |
1.8 |
|
Company included in air quality data: Shinko Fab Tech, Ltd.
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
30
50
2.5
10 |
5.3
4.0
1.0
0.43 |
|
Company included in water quality data: Shinko Fab Tech, Ltd.
| Chemical Substances |
Total substances used: 8 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Hydrogen fluoride and its water-soluble salts |
0 |
10,000 |
0 |
0 |
0 |
5,700 |
Copper sheet pickling |
| Copper water-soluble salts |
0 |
600 |
0 |
0 |
0 |
0 |
Copper plating |
| Boron & its compounds |
0 |
1,100 |
0 |
0 |
0 |
0 |
Lubricant in casting |
|
|
Daian Plant
1100 Daiancho Umedo
Inabe, Mie 511-0284
Tel +81-594-77-0330 Fax +81-594-77-2249
Main Products:
Aluminum and magnesium castings, aluminum and magnesium forgings
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler
Melting furnace |
110
120 |
72
61 |
| Dust |
Boiler
Melting furnace |
100
100 |
<2
22 |
| Dioxins |
Aluminum melting furnace |
5 |
0.011 |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
10
10
2
- |
3.0
0.7
0.2
- |
|
| Chemical Substances |
Total substances used: 4 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Methylene chloride |
3,900 |
0 |
0 |
0 |
0 |
940 |
Cleaning of fabricated aluminum products |
| Phenol |
0 |
0 |
0 |
0 |
0 |
2,200 |
Bond for sand mold casting |
| Hexavalent chromium compound |
0 |
0 |
0 |
0 |
0 |
340 |
Surface treatment for cast products |
|
|
Sun Aluminium Industries, Ltd.
260 Roppocho, Inage-ku
Chiba, Chiba 263-0004
Tel +81-43-422-1231 Fax +81-43-422-5452
Main Products:
Aluminum foil
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler |
150 |
38 |
| Dust |
Boiler |
100 |
0.3 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
-
-
-
- |
-
-
-
- |
|
| Chemical Substances |
Total substances used: 3 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Toluene |
70,000 |
0 |
0 |
0 |
0 |
3,700 |
Materials for painting and coating, adhesive |
| Xylene |
6,000 |
0 |
0 |
0 |
0 |
250 |
Materials for painting and coating, adhesive |
| Ethylbenzene |
1,100 |
0 |
0 |
0 |
0 |
25 |
Materials for painting and coating, adhesive |
|
|
Shinko Metal Products Co., Ltd.
2-1, Komorie 2-chome, Moji-ku
Kita-Kyushu, Fukuoka 800-0007
Tel +81-93-381-1331 Fax +81-93-381-3833
Main Products:
Condenser tube, copper alloy tube, composite products, heat exchangers
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Reheating furnace
Reheating furnace
Reheating furnace |
170
180
200 |
<30
24
30 |
| Dust |
Reheating furnace
Reheating furnace
Reheating furnace |
200
100
250 |
<5
<5
<5 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
30
100
5
-
|
6
8
<1
- |
|
Company included in water quality data: Japan Superconductor Technology, Inc. Moji Plant
| Chemical Substances |
Total substances used: 2 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Methylene chloride |
5,800 |
0 |
0 |
0 |
0 |
0 |
Degreasing cleaning |
| Toluene |
1,000 |
0 |
0 |
0 |
0 |
0 |
Painting |
|
|
Shinko Aluminum Wire Co., Ltd.
2153-1 Hishiki 2-chome, Nishi-ku
Sakai, Osaka 593-8315
Tel +81-72-271-1481 Fax +81-72-271-1486
Main Products:
Aluminum alloy wire, bar
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Reheating furnace |
180 |
80 |
| Dust |
Reheating furnace |
100 |
1 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
40
25
5
- |
5.1
8.4
1.5
- |
|
| Chemical Substances |
Total substances used: 1 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Trichloroethylene |
19,000 |
0 |
0 |
0 |
0 |
5,200 |
Cleaning |
|
|
Shinko-North Co., Ltd.
1758-1 Kami-Inayoshi
Kasumigaura, Ibaraki 315-8523
Tel +81-299-59-4111 Fax +81-299-59-4597
Main Products:
Temporary construction materials, automotive material and other aluminum fabricated products
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler |
In grace period |
79 |
| Dust |
Boiler |
In grace period |
10 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
15
20
5
- |
4.7
6
1
- |
|
| Chemical substances: No handling of substances requiring PRTR report |
|
Shinko Fab Tech, Ltd.
14-1 Chofu Minatomachi
Shimonoseki, Yamaguchi 752-0953
Tel +81-832-46-0210 Fax +81-832-46-1471
Main Products:
Aluminum extrusions, aluminum fabricated products
| Air Air emission data is included in Chofu Works. |
| Water Water quality data is included in Chofu Works. |
| Chemical Substances |
Total substances used: 7 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Xylene |
1,300 |
0 |
0 |
0 |
0 |
0 |
Cleaning |
| 1,3,5-trimethylbenzene |
1,300 |
0 |
0 |
0 |
0 |
0 |
Cleaning,Painting |
| Manganese and its compounds |
0 |
0 |
0 |
0 |
0 |
1,000 |
Copper alloy additives |
|
|
Shinko Leadmikk Co., Ltd.
2-1, Komorie 2-chome, Moji-ku
Kita-Kyushu, Fukuoka 800-0007
Tel +81-93-381-1337 Fax +81-93-381-3352
Main Products:
Electronic parts, semiconductor parts
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
NA |
- |
- |
| Dust |
NA |
- |
- |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
BOD
SS
Oil
Dioxins |
600
-
-
- |
33.8
-
-
- |
|
| Chemical Substances |
Total substances used: 6 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Methylene chloride |
2,700 |
0 |
0 |
0 |
0 |
50 |
Degreasing cleaning |
| Hydrogen fluoride and its water-soluble salts |
0 |
0 |
0 |
0 |
380 |
990 |
Pickling |
| Nickel compounds |
0 |
0 |
0 |
0 |
100 |
590 |
Plating process |
|
|
Niko-Aluminium Industries, Ltd.
16-1 Kinugaoka
Moka, Tochigi 321-4367
Tel +81-285-83-2131 Fax +81-285-84-0458
Main Products:
Aluminum sheet painting, aluminum slitting, aluminum sheet punching
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Reheating furnace |
230 |
28 |
| Dust |
Reheating furnace |
200 |
1 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
25
50
5
- |
3.5
1.2
<0.05
- |
|
| Chemical Substances |
Total substances used: 6 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Chromium and trivalent chromium compounds |
0 |
0 |
0 |
0 |
0 |
6,400 |
Surface treatment |
| Ethylbenzene |
180 |
0 |
0 |
0 |
0 |
89 |
Surface treatment |
| Xylene |
350 |
0 |
0 |
0 |
0 |
170 |
Surface treatment |
|
|
Kobelco & Materials Copper Tube, Ltd.
65 Hirasawa
Hadano, Kanazawa 257-0015
Tel +81-463-82-3111 Fax +81-463-83-1920
Main Products:
Copper tube for air conditioners, copper tube for hot water supply
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Melting furnace |
200 |
32 |
| Dust |
Melting furnace |
200 |
140 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
15
35
3
- |
6.5
14
<1
- |
|
| Chemical Substances |
Total substances used: 2 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Xylene |
1,800 |
0 |
0 |
0 |
0 |
600 |
Painting |
| Toluene |
1,600 |
0 |
0 |
0 |
0 |
0 |
Painting |
|
|
| Machinery & Engineering Company |
|
Harima Plant
41 Harimacho Niijima
Kako-gun, Hyogo 675-0155
Tel +81-79-436-2101 Fax +81-79-436-2199
Main Products:
Compressors
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
NA |
- |
- |
| Dust |
NA |
- |
- |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
100
90
25
- |
2.7
4
ND
- |
|
| Chemical Substances |
Total substances used: 2 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Xylene |
2,800 |
0 |
0 |
0 |
0 |
0 |
Painting |
| Ethylbenzene |
2,600 |
0 |
0 |
0 |
0 |
0 |
Painting |
|
|
Shinko Engineering Co., Ltd.
1682-2 Motoimachi
Ogaki, Gifu 503-8505
Tel +81-584-89-3121 Fax +81-584-87-0020
Main Products:
Energy systems, testing machinery, torque converters, environmental related equipment
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
NA |
- |
- |
| Dust |
Melting furnace |
200 |
43 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
BOD
SS
Oil
Dioxins |
30
40
5
- |
4.4
1.0
<1.0
- |
|
Company included in water quality data: Kobelco Construction Machinery Co., Ltd. Ogaki Factory
| Chemical Substances |
Total substances used: 3 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Xylene |
1,100 |
0 |
0 |
0 |
0 |
2,500 |
Painting |
| Toluene |
5,100 |
0 |
0 |
0 |
0 |
1,600 |
Painting |
| Ethylbenzene |
190 |
0 |
0 |
0 |
0 |
950 |
Painting |
|
|
Kobe Corporate Research Laboratories
5-5, Takatsukadai 1-chome, Nishi-ku
Kobe, Hyogo 651-2271
Tel +81-78-992-5600 Fax +81-78-992-5532
Main Products: -
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler |
150 |
43 |
| Dust |
Boiler |
100 |
<1 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
BOD
SS
Oil
Dioxins |
2,000
2,000
5
10 |
1.8
18
1
- |
|
| Chemical Substances |
Total substances used: 1 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Molybdenum and its compounds |
0 |
0 |
0 |
0 |
0 |
63 |
For testing |
|
|
Kobelco Research Institute, Inc.
(Sputtering Target Division)
3-1, Araicho Shinhama 2-chome
Takasago, Hyogo 676-86
Tel +81-79-445-9020 Fax +81-79-445-9025
Main Products:
Sputtering target
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
NA |
- |
- |
| Dust |
Melting furnace |
200 |
178 |
| Dioxins |
NA |
- |
- |
|
| Water Water quality data is included in Takasago Works. |
| Chemical Substances |
Total substances used: 3 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Silver and its water soluble compounds |
0 |
0 |
0 |
0 |
0 |
40 |
Dissolution raw material |
| Chromium and trivalent chromium compounds |
0 |
0 |
0 |
0 |
0 |
13 |
Dissolution raw material |
| Nickel |
0 |
0 |
0 |
0 |
0 |
8 |
Dissolution raw material |
|
|
Kobelco Construction Machinery Co., Ltd.
(Hiroshima Factory)
12-4 Gion 3-chome, Asa Minami-ku
Hiroshima, Hiroshima 731-0138
Tel +81-82-874-1111 Fax +81-82-874-9150
Main Products:
Construction machinery, related parts
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
NA |
- |
- |
| Dust |
NA |
- |
- |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
-
600
51)
- |
-
10
1.6
- |
|
1) Liquid petroleum
| Chemical Substances |
Total substances used: 4 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Xylene |
240,000 |
0 |
0 |
0 |
0 |
870 |
Painting |
| Ethylbenzene |
51,000 |
0 |
0 |
0 |
0 |
870 |
Painting |
| Toluene |
21,000 |
0 |
0 |
0 |
0 |
730 |
Painting |
|
|
Kobelco Construction Machinery Co., Ltd.
(Ogaki Factory)
1682-7 Motoimachi
Ogaki, Gifu 503-0932
Tel +81-584-89-3104 Fax +81-584-87-0014
Main Products:
Construction machinery, related parts
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
NA |
- |
- |
| Dust |
NA |
- |
- |
| Dioxins |
NA |
- |
- |
|
| Water Water quality data is included in Shinko Engineering Co., Ltd. |
| Chemical Substances |
Total substances used: 4 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Xylene |
52,000 |
0 |
0 |
0 |
0 |
9,200 |
Painting |
| Ethylbenzene |
6,800 |
0 |
0 |
0 |
0 |
1,100 |
Painting |
| Toluene |
11,000 |
0 |
0 |
0 |
0 |
2,900 |
Painting |
|
|
Kobelco Cranes Co., Ltd.
740 Yagi, Okubocho
Akashi, Hyogo 674-0063
Tel. +81-78-936-1331 Fax +81-78-938-2015
Main Products:
Cranes, other construction machinery
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
NA |
- |
- |
| Dust |
NA |
- |
- |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
-
600
5
- |
-
27
2.4
- |
|
| Chemical Substances |
Total substances used: 6 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Xylene |
120,000 |
0 |
0 |
0 |
0 |
0 |
Painting |
| Toluene |
68,000 |
0 |
0 |
0 |
0 |
0 |
Painting |
| Ethylbenzene |
10,000 |
0 |
0 |
0 |
0 |
0 |
Painting |
|
|
Japan Superconductor Technology Inc. (Moji Plant)
2-2-1, Komorie, Moji-ku
Kitakyushu, Fukuoka 800-0007
Tel +81-93-391-2835 Fax +81-93-391-2847
Main Products:
Superconducting wire, superconducting magnet
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
NA |
- |
- |
| Dust |
NA |
- |
- |
| Dioxins |
NA |
- |
- |
|
| Water Water quality data is included in Shinko Metal Products Co., Ltd. |
| Chemical Substances |
Total substances used: 1 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Methylene chloride |
5,000 |
0 |
0 |
0 |
0 |
0 |
Degreasing cleaning material |
|
|
Kobelco Eco-Solutions Co., Ltd. (Harima Plant)
19 Niijima, Harimacho
Kako-gun, Hyogo 675-0155
Tel +81-79-436-2500 Fax +81-79-436-2506
Main Products:
Process equipment, waste fluorescent light recycling
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Firing furnace
Firing furnace |
180
150 |
87
100 |
| Dust |
Firing furnace |
250 |
19 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
110
130
5
- |
3.7
4
2
- |
|
| Chemical Substances |
Total substances used: 2 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Methylene chloride |
1,100 |
0 |
0 |
0 |
0 |
130 |
Cleaning |
| Manganese and its compounds |
16 |
0 |
0 |
0 |
0 |
1,800 |
Welding |
|
|
Kobelco Eco-Solutions Co., Ltd.
(Technical Research Laboratory)
1-4 Murotani 1 chome,
Nishi-ku Kobe, Hyogo 651-2241
Tel. +81-78-992-6500 Fax +81-78-997-0550
Main Products: -
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
NA |
- |
- |
| Dust |
NA |
- |
- |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
BOD
SS
Oil (Animal and vegetable oil, Liquid petroleum)
Dioxins |
2,000
2,000
150/5
10 |
90
76
4/4
0.099 |
|
| Chemical substances: No handling of substances requiring PRTR report |
|
Shinko JFE Industrial Co., Ltd.
112 Kaida-Higashimachi
Kurayoshi, Tottori 682-0014
Tel +81-858-26-8111 Fax +81-858-48-1077
Main Products:
High-pressure gas vessels and other pressed parts, assembled products
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler |
260 |
84 |
| Dust |
Boiler |
300 |
11 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
-
200
-
- |
-
<1.0
-
- |
|
| Chemical Substances |
Total substances used: 4 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Xylene |
27,000 |
0 |
0 |
0 |
0 |
0 |
Painting |
| Toluene |
17,000 |
0 |
0 |
0 |
0 |
0 |
Painting |
| Ethylbenzene |
9,000 |
0 |
0 |
0 |
0 |
0 |
Painting |
|
|
Shinko Electric Co., Ltd. (Toyohashi Plant)
150 Aza-Motoyashiki, Mitsuyacho
Toyohashi, Aichi 441-3195
Tel. +81-532-41-2121 Fax +81-532-41-2179
Main Products:
Precision movement products, transport/handling products, power electronics products
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Diesel generator
Boiler
Boiler |
200
260
180 |
45
110
67 |
| Dust |
Diesel generator
Boiler |
100
300 |
32
11 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
120
20
5
- |
8.0
5
0.5
- |
|
| Chemical Substances |
Total substances used: 6 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
Toluene
|
7,700 |
0 |
0 |
0 |
0 |
0 |
Painting |
| Bisphenol A epoxy resin |
0 |
0 |
0 |
0 |
0 |
8,200 |
Painting |
| Tetrahydromethylphthalic anhydride |
0 |
0 |
0 |
0 |
0 |
3,400 |
Painting |
|
|
Shinko Electric Co., Ltd. (Ise Plant)
100 Takegahanacho
Ise, Mie 516-8550
Tel. +81-596-36-1111 Fax +81-596-36-0577
Main Products:
Precision movement products, transport/handling products, power electronics products
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler
Diesel engine |
150
950 |
63
589 |
| Dust |
Boiler
Diesel engine |
100
100 |
0
74 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
20
40
3
- |
10.7
10
<1.0
- |
|
| Chemical Substances |
Total substances used: 4 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Toluene |
7,000 |
0 |
0 |
0 |
0 |
6 |
Painting |
| Xylene |
3,300 |
0 |
0 |
0 |
0 |
13 |
Painting |
| Bisphenol A epoxy resin |
0 |
0 |
0 |
0 |
0 |
40 |
Painting |
|
|
Shinko Electric Co., Ltd. (Toba Plant)
1-19-1 Toba,
Toba, Mie 517-0011
Tel. +81-599-25-3231 Fax +81-599-25-5162
Main Products:
Motor
| Substance |
Facility |
Regulation Value |
Actual Measurement (Max.) |
| NOx |
Boiler |
180 |
91 |
| Dust |
Boiler |
300 |
22 |
| Dioxins |
NA |
- |
- |
|
Water
| Substance |
Regulation Value |
Actual Measurement (Max.) |
COD
SS
Oil
Dioxins |
-
-
-
- |
-
-
-
- |
|
| Chemical Substances |
Total substances used: 2 |
| Substance |
Amount of Emission |
Amount Transferred
|
Main use or process |
| Air |
Public water |
Soil |
Landfill within facility |
Sewerage |
Off-site |
| Toluene |
2,900 |
0 |
0 |
0 |
0 |
0 |
Painting |
| Styrene |
1,600 |
0 |
0 |
0 |
0 |
16 |
Varnish application for coiling process |
|
|
|