Home > About Us > Corporate Social Responsibility > Sustainability Report > Sustainability Report 2007 > Emission Data of Production Facilities

Environmental Management
Sustainability Report 2007

Emission Data of Production Facilities
The following is the data on exhaust gas and wastewater emissions as well as major chemical substance emissions or transfers from all works, plants and facilities of Kobe Steel and its major group companies. The tables show regulation values and actual emissions of exhaust gases (NOx, dust and dioxins) and major elements of wastewater emissions, such as chemical oxygen demand (COD) including biochemical oxygen demand (BOD), suspended solids (SS), oil and dioxins.

The emission data includes data from group companies administered by Kobe Steel and operating on the premises of Kobe Steel's facilities.

Air Quality Data
* Regulation values are based on the Air Pollution Control Law, prefectural government ordinances, and the Law Concerning Special Measures against Dioxins.
* Unit: ppm for NOx, mg/Nm3 for dust, and ng-TEQ/ Nm3for dioxins
* Regulation values are set separately for each facility.
* The following substances are excluded from the tables because their emissions do not reach the quantitative limit or are lower than the numerical targets: SOx, cadmium, chlorine, hydrogen chloride, fluorine, hydrogen fluoride and silicon fluoride, lead, benzene, trichloroethylene, dioxin.
Water Quality Data
* Regulation values are based on the Water Pollution Control Law, prefectural government ordinances, the Law Concerning Special Measures against Dioxins, the Sewage Water Law, and municipal government ordinances concerning sewage water.
* Unit: mg/l, pg-TEQ/l for dioxins
* ND (Not detected): Below the quantitative limit
* The following substances are excluded from the tables because their emissions do not reach the quantitative limit or are lower than the numerical targets: pH, BOD, total nitrogen, total phosphorous, phenols, total chromium, soluble iron, soluble manganese, fluorine, copper, zinc, cadmium, total cyanide, organic phosphorus compounds, lead, hexavalent chromium, arsenic, total mercury, alkyl mercury, PCB, trichloroethylene, tetrachloroethylene, dichloromethane, carbon tetrachloride, 1,2-dichloroethane, 1,1-dichloroethylene, cis-1,2-dichloroethylene, 1,1,1-trichloroethane, 1,1,2-trichloroethane, 1,3-dichloropropene, thiram, simazine, thiobencarb, benzene, selenium
Chemical substances
* Unit: kg (mg-TEQ for dioxins)


Iron & Steel


Kakogawa Works
1 Kanazawacho
Kakogawa, Hyogo 675-0137
Tel +81-79-436-1111 Fax +81-79-436-1400

Main Products:
Steel plate, hot-rolled sheet, cold-rolled sheet, coated sheet, wire rod


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler
Boiler
Reheating furnace
250
190
100
16-51
33-54
18-50
Dust Boiler
Boiler
Reheating furnace
100
70
150
2-11
2-34
0-4
Dioxins Sintering plant
Industrial waste incinerator
1
5
0.34
0.18
NOx: For a period of time in April 2006, the boiler's oxygen concentration gauge exceeded the acceptable range, making it possible that regulation values for NOx were exceeded.
SOx: In June 2006, emissions from the boiler exceeded regulation values. In both of the above cases, appropriate countermeasures were implemented and regulation values have not been exceeded since.


Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
20
40
1.5 1)
10
0.5-5.0
1-20
<1
0.078
1) Liquid petroleum
Companies included in emissions data: Kansai Coke and Chemicals Co., Ltd.

Chemical Substances Total substances used: 21
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Toluene 15,000 0 0 0 0 450 Painting
Hydrogen fluoride and its water-soluble salts 0 11,000 0 0 0 2,000 Rolling, pickling of steel surface
Xylene 12,000 0 0 0 0 2,600 Painting

Kobe Works
2 Nadahama Higashicho, Nada-ku
Kobe, Hyogo 657-0863
Tel +81-78-882-8030 Fax +81-78-882-8290

Main Products:
Steel wire rod and bar


Air  
Substance Facility Regulation Value Actual Measurement
NOx Boiler
Boiler
Reheating furnace
250
130
100
6-284 1)
0.3-84
3-72
Dust Boiler
Boiler
Reheating furnace
200
50
150
35-96
<1-1
6-9
Dioxins Industrial waste incinerator 10 0.9
1)Regulation values were exceeded in May 2006. Appropriate countermeasures were implemented and regulation values have not been exceeded since.

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
15
30
1 1)
10
1.0-4.9
1-19
<1
0.0021
1) Liquid petroleum

Chemical Substances Total substances used: 13
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Manganese and its compounds 17 59 0 0 0 9,400 Steelmaking process
Chromium and trivalent chromium compounds 8 7.3 0 0 0 2,100 Steelmaking process
Polyoxyethylene Nonylphenyl Ether 0 0 0 0 0 2,500 Steelmaking process

Takasago Works
3-1, Araicho Shinhama 2-chome
Takasago, Hyogo 676-8670
Tel +81-79-445-7111 Fax +81-79-445-7231

Main Products:
Steel castings and forgings, titanium products, steel powder, industrial machinery, compressors, equipment for the energy and nuclear fields


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler
Reduction furnace for steel powder
Reheating furnace
130
150
200
57
26
43
Dust Boiler
Reduction furnace for steel powder
Reheating furnace
50
100
100
1
6
1
Dioxins Industrial waste incinerator
Electric arc furnace (for steel powder)
-
5
Suspended
0.000015
Companies included in emissions data: EarthTechnica Co., Ltd.

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
10
24
1
NA
3.2
4.0
<0.5
-

Chemical Substances Total substances used: 12
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Methylene chloride 68,000 10 0 0 0 0 Degreasing cleaning of titanium scrap
Xylene 66,000 0 0 0 0 400 Painting
Toluene 28,000 0 0 0 0 770 Contained in binding agent for steel powder

Shinko Kenzai, Ltd.
46 Marushimacho
Amagasaki, Hyogo 660-0086
Tel +81-6-6418-2621 Fax +81-6-6418-6701

Main Products:
Guardrails, grating, anti-slip steel plate, aluminum road material


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler 150 43-48
Dust Boiler 100 <1
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
300
300
5
NA
8.33
4.34
1.26
-

Chemical Substances Total substances used: 1
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Xylene 8,800 0 0 0 0 0 Painting

Shinko Wire Company, Ltd. (in Amagasaki)
10-1 Nakahamacho
Amagasaki, Hyogo 660-0091
Tel +81-6-6411-1071 / Fax +81-6-6411-9644

Main Products:
Steel wire products, wire for prestressed concrete, steel strand for prestressed concrete, steel bar for prestressed concrete


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler
Reheating furnace
150
130
62
17
Dust Boiler
Reheating furnace
100
200
<1
20
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
20
30
22
NA
3.4
3.5
0
-

Chemical Substances Total substances used: 3
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Tetrachloroethylene 13,300 0 0 0 0 5,600 Degreasing cleaning
Trichloroethylene 9,400 0 0 0 0 0 Coating agent
Lead and its compounds 0 11 0 0 0 7,800 Lead for heat treatment

Shinko Wire Company, Ltd. (in Onoecho)
128 Imafuku, Onoecho
Kakogawa, Hyogo 675-0027
Tel +81-79-424-2681 Fax +81-79-424-2686

Main Products:
Steel wire products, wire for prestressed concrete, steel strand for prestressed concrete, steel bar for prestressed concrete


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler
Reheating furnace
150
200
56
1.8
Dust Boiler
Reheating furnace
100
250
12
1
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
15
25
2
NA
3.0-5.4
1-3
0.1-0.8
-

Chemical Substances Total substances used: 1
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Lead and its compounds 0 4 0 0 0 1,500 Lead for heat treatment

Kobe Special Tube Co., Ltd.
13-1 Chofu Minatomachi
Shimonoseki, Yamaguchi 752-0953
Tel +81-832-46-3781 Fax +81-832-45-1092

Main Products:
Seamless stainless steel tube, precision tube, specialty tube


Air
Substance Facility Regulation Value Actual Measurement
NOx Reheating furnace 180 85
Dust Reheating furnace 0.2 0.021
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
25
50
5
NA
8.1
8
3
-

Chemical Substances Total substances used: 2
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Hydrogen fluoride and its water-soluble salts 260 2,300 0 0 0 10 Pickling
Trichloroethylene 0 0 0 0 0 0 Lubricant

Shinko Bolt, Ltd.
17 Futamata Shinmachi
Ichikawa, Chiba 272-0002
Tel +81-47-328-6551 Fax +81-47-328-6558

Main Products:
High strength bolts, various other bolts


Air
Substance Facility Regulation Value Actual Measurement
NOx NA - -
Dust NA - -
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
BOD
SS
Oil
Dioxins
25
70
3
NA
5
6
1
-

Ceratechno Co., Ltd. (Akashi Plant)
11-70, Kisaki 5-chome
Akashi, Hyogo 673-0037
Tel +81-78-923-8678 Fax +81-78-923-8397


Main Products:
Refractory bricks, monolithic refractories, burnt lime


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler
Reheating furnace (Dry Kiln)
180
180
64
10
Dust Boiler
Reheating furnace (Dry Kiln)
300
300
12
7
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
40
32
3.2
NA
7.4
5.6
1.8
-

Chemical Substances Total substances used: 6
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Ethylene glycol 28,000 0 0 0 0 51 Brick binder
Chromium and trivalent chromium compounds 0 0 0 0 0 9,400 Filler sand material
Phenol 290 0 0 0 0 7.1 Brick binder

Ceratechno Co., Ltd. (Bizen Plant)
2835-7 Honami
Bizen, Okayama 705-0033
Tel +81-869-67-0011 Fax +81-869-67-1346

Main Products:
Refractory bricks, monolithic refractories, burnt lime


Air
Substance Facility Regulation Value Actual Measurement
NOx Reheating furnace (Firing furnace) 450 25-28
Dust Reheating furnace (Firing furnace) 200 6-24
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
30
120
5 1)
NA
1.3
<1
<0.5
-
1)Liquid petroleum

Chemical Substances Total substances used: 4
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Ethylene glycol 22,000 0 0 0 0 140 Brick binder
Phenol 9,500 0 0 0 0 58 Brick binder
Boron and its compounds 0 0 0 0 0 48 Castable materials

Tesac Wirerope Co., Ltd.
11-1 Nishiki Nakamichi
Kaizuka, Osaka 597-8501
Tel +81-72-432-9251 Fax +81-72-432-2339

Main Products:
Wire rope


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler
Reheating furnace
150
100
16.3
4.3
Dust Boiler
Reheating furnace
150
100
15.3
5.1
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
300
300
NA
NA
19.2
8.4
-
-

Chemical Substances Total substances used: 2
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Methylene chloride 6,800 0 0 0 0 0 Wire drawing process
Toluene 1,800 0 0 0 0 0 Painting

Nippon Koshuha Steel Co., Ltd.
10-15, Hachimanmachi 3-chome
Imizu, Toyama 934-8502
Tel +81-766-84-3181 Fax +81-766-84-3468

Main Products:
Specialty steel forged products (die steel, plastic mold steel, other precision forged steels), specialty rolled steel


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler
Melting furnace
Reheating furnace
180
-
170
42
9.6
28.5
Dust Boiler
Melting furnace
Reheating furnace
200
100
200
39.5
1.1
4.5
Dioxins Electric arc furnace - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
20
50
3
NA
3.7
8.5
0.9
-

Chemical Substances Total substances used: 8
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Hydrogen fluoride and its water-soluble salts 730 12,000 0 0 0 270,000 Secondary raw material for steelmaking
Manganese and its compounds 2,400 180 0 0 0 40,000 Raw material for steelmaking
Water-soluble zinc compounds 0 580 0 0 0 16,000 Surface treatment

Kansai Coke and Chemicals Co., Ltd.
(Kakogawa Plant)

7 Kanazawacho
Kakogawa, Hyogo 675-0137
Tel +81-79-436-1500 Fax +81-79-435-1626

Main Products:
Coke, coke oven gas, chemical products


Air
Substance Facility Regulation Value Actual Measurement
NOx Coke oven
Reheating furnace
Sulfuric acid manufacturing reactor
350
200
200
135-251
34-83
34-55
Dust Coke oven
Reheating furnace
Sulfuric acid manufacturing reactor
150
150
200
0-10
0-1
0-1
Dioxins NA - -

Chemical Substances Total substances used: 4
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Benzene 8,100 0 0 0 0 0 Coke oven
Toluene 2,000 0 0 0 0 0 Coke oven
Xylene 370 0 0 0 0 0 Coke oven
Emissions data of water included in Kakogawa Works

Shinko Kobe Power Inc.
2 Nadahama Higashicho, Nada-ku
Kobe, Hyogo 657-0863
Tel +81-78-882-8036 Fax +81-78-882-8037

Main Products:
Generation and wholesale supply of electricity


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler 24 1-17
Dust Boiler 10 <1-3
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
15
30
1
NA
1.4-5.0
2-13
<1
-


Chemical Substances Total substances used: 1
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Hydrazine 0 0 0 0 0 0 Power generation boiler


Welding Company


Fujisawa Industrial Operations
100-1 Miyamae
Fujisawa, Kanagawa 251-8551
Tel +81-466-20-3111 Fax +81-466-20-3115

Main Products:
Semi-automatic welding wires


Air
Substance Facility Regulation Value Actual Measurement
NOx NA - -
Dust NA - -
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
60
90
10 1)
NA
5.2-5.7
3.5-11.6
0.8-2.0
-
1) Liquid petroleum
Data includes air and water emission data from subsidiary Shinko Taseto.

Ibaraki Plant
2-19 Higashi-Unobecho
Ibaraki, Osaka 567-0879
Tel +81-72-621-2111 Fax +81-72-620-2051

Main Products:
Covered welding electrodes, semi-automatic welding wires, fluxes, backing materials


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler
Calcination furnace
Dry Kiln
150
-
230
33
55
37
Dust Boiler
Calcination furnace
Dry Kiln
100
250
200
<0.1
<0.1
0.4
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
-
300 1)
5 1) 2)
NA
3.7-29.0
3.2-11.6
0.40-1.60
-
1) Ibaraki municipal sewage ordinance
2) Liquid petroleum


Chemical Substances Total substances used: 7
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Manganese and its compounds 9 0 0 0 0 20,000 Added to welding wire
Molybdenum and its compounds 2 0 0 0 0 17,000 Added to welding wire
Chromium and trivalent chromium compounds 1 0 0 0 0 2,300 Added to stainless steel welding wire

Saijo Plant (Welding)
6400-1, Saijocho Misonou
Higashi-Hiroshima, Hiroshima 739-0024
Tel +81-82 423-3311 Fax +81-82-420-0038

Main Products:
Covered welding electrodes, high-functional materials


Air
Substance Facility Regulation Value Actual Measurement
NOx Dry Kiln 230
1-37
Dust Dry Kiln 200 1-5
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
BOD
SS
Oil
Dioxins
-
-
5 1) 2)
NA
140-448
1.2-23.0
0.1-0.9
-
1) Higashi-Hiroshima municipal sewage ordinance
2) Liquid petroleum


Chemical Substances Total substances used: 2
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Manganese and its compounds 23 0 0 0 0 7,200 Added to welding electrode
Xylene 320 0 0 0 0 0 Contained in kerosene

Shinko Actec Co., Ltd.
682 Iwanaka, Hidakacho
Toyooka, Hyogo 669-5302
Tel +81-796-42-1212 Fax +81-796-42-1218

Main Products:
High functional filters, odor eliminators


Air
Substance Facility Regulation Value Actual Measurement
NOx NA - -
Dust NA - -
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
-
-
Mineral oil, 5mg/l; animal fat and vegetable oil, 30mg/l
NA
6.4
-
<0.1
-

Chemical Substances Total substances used: 1
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Manganese and its compounds 0 0 0 0 8 350 Raw material in high functional filters

Shinko Taseto Co., Ltd.
100-1 Miyamae
Fujisawa, Kanagawa 251-8551
Tel +81-466-20-3131 Fax +81-466-20-3115

Main Products:
Flux-cored welding wires, solid welding wires


Chemical Substances Total substances used: 6
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Molybdenum and its compounds 0 0 0 0 0 3,400 Lubricant in drawing process
Chromium and trivalent chromium compounds
0 0 0 0 0 650 Added to welding wire
Manganese and its compounds 0 0 0 0 0 460 Added to welding wire
Emissions data of air and water included in Fujisawa Industrial Operations

Hanshin Yosetsu Kizai Co., Ltd.
1028-12 Mitsuita
Okayama, Okayama 709-2105
Tel +81-867-24-4181 Fax +81-867-24-4340

Main Products:
Flux for automatic welding


Air
Substance Facility Regulation Value Actual Measurement
NOx Dry Kiln 250 25
Dust Melting furnace
Dry Kiln
200
200
95
13
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
BOD
COD
SS
Dioxins
30
30
30
NA
8.4
13.0
2.0
-

Chemical Substances Total substances used: 8
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Manganese and its compounds 56 0 0 0 0 15,000 Raw material for flux
Boron & its compounds 0.8 0 0 0 0 220 Raw material for flux
Chromium and trivalent chromium compounds 0.9 0 0 0 0 230 Raw material for flux

Kobe Welding Wire Co. Ltd.
3-36 Osadanocho
Fukuchiyama, Kyoto 620-0853
Tel +81-773-27-2131 Fax +81-773-27-6358

Main Products:
Solid welding wires


Air
Substance Facility Regulation Value Actual Measurement
NOx Reheating furnace
180 80 - 130
Dust Reheating furnace
200 ND-9
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
-
600
5
NA
0.5-2.3
ND-0.8
ND
-

Chemical Substances Total substances used: 3
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Molybdenum and its compounds 0 0 0 0 0 2,900 Lubricant in drawing process
Inorganic cyanide compounds 0 0 0 0 0 690 Plating process
Water-soluble copper salts 0 0 0 0 1.1 0 Plating process




Aluminum & Copper Company


Moka Plant
No. 2 Kogyo Danchi 15 Kinugaoka
Moka, Tochigi 321-4367
Tel +81-285-82-4111 Fax +81-285-84-0231

Main Products:
Aluminum sheet and strip


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler
Melting furnace
Reheating furnace
250
200
130
98
87
44
Dust Boiler
Melting furnace
Reheating furnace
300
200
250
7
24
2
Dioxins Industrial waste incinerator
Aluminum melting furnace
10
5
0.0047
0.011

Water
Substance Regulation Value Actual Measurement
BOD
SS
Oil
Dioxins
25
50
5 1)
NA
6.1
4.6
<1.0
-
1) Liquid petroleum

Chemical Substances Total substances used: 15
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Chromium and trivalent chromium compounds 0 0 0 0 0 27,000 Surface treatment of aluminum sheet
Xylene 3,600 0 0 0 0 530 Contained in kerosene
Manganese and its compounds 0 0 0 0 0 14,000 Added to molten aluminum

Chofu Works
14-1 Minatomachi, Chofu
Shimonoseki, Yamaguchi 752-0953
Tel +81-832-46-1211 Fax +81-832-46-1271

Main Products:
Aluminum extrusions, fabricated aluminum products, copper sheet and strip


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler
Melting furnace
Reheating furnace
150
180
180
13
42
64
Dust Boiler
Melting furnace
Reheating furnace
200
300
300
<5
20
<5
Dioxins Aluminum melting furnace 5 0.1

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
30
50
2.5
5
5.2
2.3
1
0.55

Chemical Substances Total substances used: 7
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Hydrogen fluoride and its water-soluble salts 0 12,800 0 0 0 3,900 Copper sheet pickling
Xylene 610 0 0 0 0 0 Contained in kerosene
Boron & its compounds 0 2,000 0 0 0 0 Lubricant in casting
Air and water emissions include data from Shinko Fab Tech, Ltd.

Daian Plant
1100 Daiancho Umedo
Inabe, Mie 511-0284
Tel +81-594-77-0330 Fax +81-594-77-2249

Main Products:
Aluminum and magnesium castings, aluminum and magnesium forgings


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler
Melting furnace
Reheating furnace
110
120
120
53
44.5
66
Dust Boiler
Melting furnace
Reheating furnace
100
100
100
2
15
2
Dioxins Aluminum melting furnace 5 0.25

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
10
10
2
-
1.5
<2
<0.5
-

Chemical Substances Total substances used: 3
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Methylene chloride 5,200 0 0 0 0 980 Cleaning of fabricated aluminum products
Phenol 0 0 0 0 0 2,300 Bond for sand mold casting
Dioxins 0.2 0 0 0 0 0 Aluminum melting furnace

Sun Aluminium Industries, Ltd.
260 Roppocho, Inage-ku
Chiba, Chiba 263-0004
Tel +81-43-422-1231 Fax +81-43-422-5452

Main Products:
Aluminum foil


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler 150 34
Dust Boiler 100 0.2
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
90
50
5
NA
7.6
-
-
-

Chemical Substances Total substances used: 3
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Toluene 62,000 0 0 0 0 3,200 Materials for painting and coating, adhesive
Xylene 9,400 0 0 0 0 270 Materials for painting and coating, adhesive
Ethylbenzene 1,400 0 0 0 0 27 Materials for painting and coating, adhesive

Shinko Metal Products Co., Ltd.
2-1, Komorie 2-chome, Moji-ku
Kita-Kyushu, Fukuoka 800-0007
Tel +81-93-381-1331 Fax +81-93-381-3833

Main Products:
Condenser tube, copper alloy tube, composite products, heat exchangers


Air
Substance Facility Regulation Value Actual Measurement
NOx Reheating furnace 200 42
Dust Boiler
Melting furnace
Reheating furnace
300
200
250
<5
<5
<5
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
Maximum: 30mg/l (Daily average: 20mg/l )
Maximum: 100mg/l (Daily average: 70mg/l )
5mg/l
NA
1.4-4.8
1.0-8.0
<1.0
-

Chemical Substances Total substances used: 2
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Methylene chloride 5,400 0 0 0 0 0 Degreasing cleaning
Toluene 1,300 0 0 0 0 0 Painting

Shinko Aluminum Wire Co., Ltd.
2153-1 Hishiki 2-chome, Nishi-ku
Sakai, Osaka 593-8315
Tel +81-72-271-1481 Fax +81-72-271-1486

Main Products:
Aluminum alloy wire, bar


Air
Substance Facility Regulation Value Actual Measurement
NOx Reheating furnace 200 40
Dust Reheating furnace 25 1
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
40
25
5
NA
7.9
18.8
1.1
-

Chemical Substances Total substances used: 1
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Trichloroethylene 13,000 0 0 0 0 5,600 Cleaning

Shinko-North Co., Ltd.
1758-1 Kami-Inayoshi
Kasumigaura, Ibaraki 315-8523
Tel +81-299-59-4111 Fax +81-299-59-4597

Main Products:
Temporary construction materials, automotive material and other aluminum fabricated products


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler - -
Dust Boiler - -
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
15
20
5
NA
6.5
6.7
<1
-

Chemical Substances Total substances used: 1
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Bisphenol A epoxy resin 0 0 0 0 0 0 Adhesive

Shinko Fab Tech, Ltd.
14-1 Chofu Minatomachi
Shimonoseki, Yamaguchi 752-0953
Tel +81-832-46-0210 Fax +81-832-46-1471

Main Products:
Aluminum extrusions, aluminum fabricated products


Chemical Substances Total substances used: 7
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Xylene 1,200 0 0 0 0 0 Cleaning
1,3,5-trimethylbenzene 1,100 0 0 0 0 0 Cleaning, painting
Manganese and its compounds 0 0 0 0 0 990 Copper alloy additives
Air and water emissions data includes emissions from Chofu Plant.

Shinko Leadmikk Co., Ltd.
2-1, Komorie 2-chome, Moji-ku
Kita-Kyushu, Fukuoka 800-0007
Tel +81-93-381-1337 Fax 81-93-381-3352

Main Products:
Electronic parts, semiconductor parts


Air
Substance Facility Regulation Value Actual Measurement
NOx NA - -
Dust NA - -
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
CN
Cu
Pb
F
1
3
0.1
8
0.032
0.009
<0.005
1.146

Chemical Substances Total substances used: 6
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Methylene chloride 5,400 0 0 0 0 270 Degreasing cleaning
Hydrogen fluoride and its water-soluble salts 0 0 0 0 300 1,400 Pickling
Inorganic cyanide compounds 0 0 0 0 6 930 Plating process

Niko-Aluminium Industries, Ltd.
16-1 Kinugaoka
Moka, Tochigi 321-4367
Tel +81-285-83-2131 Fax +81-285-84-0458

Main Products:
Aluminum sheet painting, aluminum slitting, aluminum sheet punching


Air
Substance Facility Regulation Value Actual Measurement
NOx Dry Kiln 230 dai 42
Dust Dry Kiln 200 dai1
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
BOD
SS
Oil
Dioxins
25
50
5
NA
2.28
1.45
0.53
-

Chemical Substances Total substances used: 4
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Chromium and trivalent chromium compounds 0 0 0 0 0 4,100 Surface treatment
Xylene 190 0 0 0 0 94 Painting
Hydrogen fluoride and its water-soluble salts 0 0 0 0 0 0 Painting

Kobelco & Materials Copper Tube, Ltd.
65 Hirasawa
Hadano, Kanazawa 257-0015
Tel +81-463-82-3111 Fax +81-463-83-1920

Main Products:
Copper tube for air conditioners, copper tube for hot water supply


Air
Substance Facility Regulation Value Actual Measurement
NOx Melting furnace 200 26-34
Dust Melting furnace 200 41-60
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
15
35
3
NA
3.5-8.7
2.0-33.0
1.0-1.9
-

Chemical Substances Total substances used: 2
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Xylene 1,600 0 0 0 0 600 Painting
Toluene 2,100 0 0 0 0 0 Painting




Machinery & Engineering Company


Harima Plant
41 Harimacho Niijima
Kako-gun, Hyogo 675-0155
Tel +81-79-436-2101 Fax +81-79-436-2199

Main Products:
Compressors


Air
Substance Facility Regulation Value Actual Measurement
NOx NA - -
Dust NA - -
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
100
90
25
NA
4
2
0.5
-

Chemical Substances Total substances used: 2
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Xylene 3,000 0 0 0 0 0 Painting
Ethylbenzene 2,500 0 0 0 0 0 Painting

EarthTechnica Co., Ltd. (Yachiyo Plant)
1780 Kamitakano,
Yachiyo, Chiba 276-0022
Tel +81-47-483-1111 Fax +81-47-482-3227

Main Products:
Crushing equipment


Air
Substance Facility Regulation Value Actual Measurement
NOx Melting furnace
Reheating furnace
-
200
-
101
Dust Melting furnace
Reheating furnace
200
250
0.25
12.3
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
BOD
SS
Oil
Dioxins
25
70
3
NA
1.1
7.5
ND
-

Chemical Substances Total substances used: 4
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Manganese and its compounds 200 0 0 0 0 32,000 Melting cast steel
Chrome and trivalent chrome compounds 59 0 0 0 0 25,000 Melting cast steel
Molybdenum and its compounds 1.4 0 0 0 0 410 Melting cast steel



Head Office


Kobe Corporate Research Laboratories
5-5, Takatsukadai 1-chome, Nishi-ku
Kobe, Hyogo 651-2271
Tel +81-78-992-5600 Fax +81-78-992-5532

Main Products:
-


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler
Melting furnace
150
180
39-47
72-90
Dust Boiler
Melting furnace
100
200
<1
<1
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
BOD
SS
Oil
Dioxins
2,000
2,000
5
NA
0.8
1
1
-

Kobelco Research Institute, Inc.
(Sputtering Target Division)

3-1, Araicho Shinhama 2-chome
Takasago, Hyogo 676-8670
Tel +81-79-445-9020 Fax +81-79-445-9025

Main Products:
Sputtering target


Air
Substance Facility Regulation Value Actual Measurement
NOx NA - -
Dust Melting furnace 200 73
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
NA
NA
NA
NA
-
-
-
-

Chemical Substances Total substances used: 6
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Silver and its water soluble compounds 0 0 0 0 0 27 Dissolution raw material
Molybdenum and its compounds 0 0 0 0 0 9 Dissolution raw material
Nickel 0 0 0 0 0 10 Dissolution raw material

Kobelco Construction Machinery Co., Ltd.
(Hiroshima Factory)

12-4 Gion 3-chome, Asa Minami-ku
Hiroshima, Hiroshima 731-0138
Tel +81-82-874-1111 Fax +81-82-874-9150

Main Products:
Construction machinery, related parts


Air
Substance Facility Regulation Value Actual Measurement
NOx NA - -
Dust NA - -
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
NA
600
<30 1),<5 2)
NA
-
3.9 3)
0.88 3)
-
1)Animal and vegetable oil
2)Liquid petroleum
3)Average value


Chemical Substances Total substances used: 4
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Xylene 260,000 0 0 0 0 440 Painting
Ethylbenzene 35,000 0 0 0 0 440 Painting
Toluene 15,000 0 0 0 0 360 Painting

Kobelco Cranes Co., Ltd.
740 Yagi, Okubocho
Akashi, Hyogo 674-0063
Tel. +81-78-936-1331 Fax +81-78-938-2015

Main Products:
Cranes, other construction machinery


Air
Substance Facility Regulation Value Actual Measurement
NOx NA - -
Dust NA - -
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
NA
600
5
NA
-
4-34
<0.5-4.5
-

Chemical Substances Total substances used: 5
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Xylene 87,000 0 0 0 0 0 Painting
Toluene 47,000 0 0 0 0 0 Painting
Ethylbenzene 6,700 0 0 0 0 0 Painting

Japan Superconductor Technology Inc. (Moji Plant)
2-2-1, Komorie, Moji-ku
Kitakyushu, Fukuoka 800-0007
Tel +81-93-391-2835 Fax +81-93-391-2847

Main Products:
Superconducting wire, superconducting magnet


Air
Substance Facility Regulation Value Actual Measurement
NOx Reheating furnace 150 3
Dust Reheating furnace 200 5
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
NA
NA
NA
NA
-
-
-
-

Chemical Substances Total substances used: 4
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Methylene chloride 1,900 0 0 0 0 0 Degreasing cleaning material

Kobelco Eco-Solutions Co., Ltd. (Harima Plant)
19 Niijima, Harimacho
Kako-gun, Hyogo 675-0155
Tel +81-79-436-2500 Fax +81-79-436-2506

Main Products:
Process equipment, waste fluorescent light recycling


Air
Substance Facility Regulation Value Actual Measurement
NOx Reheating furnace 180 92
Dust Reheating furnace 25 6
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
28
9
5
NA
3.2
8
<2.0
-

Chemical Substances Total substances used: 3
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Methylene chloride 1,300 0 0 0 0 160 Cleaning
Manganese and its compounds 19 0 0 0 0 2,600 Welding

Kobelco Eco-Solutions Co., Ltd.
(Technical Research Laboratory)

1-4 Murotani 1 chome,
Nishi-ku Kobe, Hyogo 651-2241
Tel. +81-78-992-6500 Fax +81-78-997-0550

Main Products:
-


Air
Substance Facility Regulation Value Actual Measurement
NOx NA - -
Dust NA - -
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
BOD
SS
Oil
Dioxins
2,000
2,000
-
10
7
2
-
-

Shinko JFE Industrial Co., Ltd.
112 Kaida-Higashimachi
Kurayoshi, Tottori 682-0014
Tel +81-858-26-8111 Fax +81-858-48-1077

Main Products:
High-pressure gas vessels and other pressed parts, assembled products


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler 260 83
Dust Boiler 300 6
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
NA
200
5
NA
-
<1.0
<0.5
-

Chemical Substances Total substances used: 1
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Xylene 29,000 0 0 0 0 0 Painting
Toluene 18,000 0 0 0 0 0 Painting
Ethylbenzene 9,700 0 0 0 0 0 Painting

Shinko Engineering Co., Ltd.
1682-2 Motoimachi
Ogaki, Gifu 503-8505
Tel +81-584-89-3121 Fax +81-584-87-0020

Main Products:
High-speed diesel engines, gas engines, torque converters, cogeneration systems, testing machinery


Air
Substance Facility Regulation Value Actual Measurement
NOx NA - -
Dust Melting furnace 200 48
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
BOD
SS
Oil
Dioxins
30
40
5
NA
-
<1
<1
-

Chemical Substances Total substances used: 3
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Xylene 830 0 0 0 0 1,900 Painting
Toluene 4,900 0 0 0 0 1,500 Painting
Ethylbenzene 230 0 0 0 0 1,100 Painting

Shinko Electric Co., Ltd. (Toyohashi Plant)
150 Aza-Motoyashiki, Mitsuyacho
Toyohashi, Aichi 441-3195
Tel. +81-532-41-2121 Fax +81-532-41-2179


Main Products:
Precision movement products, transport/handling products, power electronics products


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler 180 63
Dust Boiler 300 33
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
BOD
SS
Oil
Dioxins
120
20
5
NA
4.7
3.7
0.5
-

Chemical Substances Total substances used: 5
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Toluene
11,000 0 0 0 0 0 Painting
Bisphenol A epoxy resin 0 0 0 0 0 7,400 Painting
Tetrahydromethylphthalic anhydride 0 0 0 0 0 7,000 Painting

Shinko Electric Co., Ltd. (Ise Plant)
100 Takegahanacho
Ise, Mie 516-8550
Tel. +81-596-36-1111 Fax +81-596-36-0577

Main Products:
Precision movement products, transport/handling products, power electronics products


Air
Substance Facility Regulation Value Actual Measurement
NOx Boiler 180 82
Dust Boiler 300 100
Dioxins NA - -

Water
Substance Regulation Value Actual Measurement
COD
SS
Oil
Dioxins
20
40
3
-
8
7
<1.0
-

Chemical Substances Total substances used: 3
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Toluene 7,100 0 0 0 0 23 Painting
Xylene 3,100 0 0 0 0 24 Painting
Bisphenol A epoxy resin 0 0 0 0 0 61 Painting

Shinko Electric Co., Ltd. (Toba Plant)
1-19-1 Toba,
Toba, Mie 517-0011
Tel. +81-599-25-3231 Fax +81-599-25-5162

Main Products:
Motor


Chemical Substances Total substances used: 3
Substance Amount of Emission Amount
Transferred
Main use or process
Air Public
water
Soil Landfill
within
facility
Sewerage Off-
site
Toluene 3,600 0 0 0 0 0 Painting
Styrene 1,100 0 0 0 0 11 Varnish application for coiling process
Bisphenol A epoxy resin 0 0 0 0 0 38 Mold processing for coiling process